您现在的位置:网站首页>Knowledge base

Precautions for the use of electric bed in operating room

2022
11/12
被阅读:517次

Precautions for the use of electric bed in operating room

1. Evaluation points

Whether the power cord of the electric bed is in good condition and not exposed. Whether the screw of the electric bed is loose.

2. Operation method

Check whether the accessories of the operating bed are complete and safe, and whether the connections are tight;

Turn on the power supply, turn on the switch, whether it is in a normal standby state;

Use the electronic controller to adjust the position of the bed according to the needs of the operation;

At the end of the operation, adjust it to the horizontal position and reduce it to the minimum;

Turn off the power switch, unplug the plug, and place the power cord in a proper position.

3. Matters needing attention

A. Make sure that the operating bed is locked before placing the position;

B. The center of the surgical site of the operating bed should be facing the central axis of the shadowless lamp to facilitate the adjustment of the operating light;

C. The awake patient informs the patient that the operating bed is narrow and cannot be moved to prevent falling from the bed, and inform the bed first;

D. When the patient is inclined at a relatively large angle (left and right, head and foot), make sure that the patient has been fixed correctly;

E. Do not put the hand board on the side rails of the head board; after the head and foot boards are folded down, care should be taken to avoid collision with the base or the ground;

F. During the adjustment process of the electric bed, it is necessary to pay attention to that the lines of the bed are not damaged by pressure to maintain the integrity of the insulating layer;

G. Remove the stains on the mattress in time, and use 20% alcohol to clean and disinfect;

H. The operating table should be wiped with a damp cloth with clean water before and after use to keep it dry and clean;

I. It is strictly forbidden to rinse with water. When disinfecting the floor, the bottom wheel of the operating table should be dropped and pushed to a dry place.

snbase9900


Precautions for the use of electric bed in operating room
上一条:Operation process and maintenance of fully automatic delivery bed下一条:The difference between halogen light source and led light source of surgical shadowless lamp

Contact

Phone: + 86 17717554373
Email: admin01@chinakej.com


Add: 1-1,No 3 building,NO 618,jianyun road,zhoupu town,pudong new district,shanghai city,China



Copyright @JAVIN MEDICAL TECHNOLOGY CO.,LTD.